Echo | Angio | ECG | X-Ray/MRI | Clinical Trials | Guidelines | Drug Info |  Journals  | Events | Interesting Cases

Welcome May 21, 2013
Search News by Date
  



The CARILLION® Mitral Contour System implanted in heart failure patients with functional mitral regurgitation provide clinical improvements

The CARILLION® Mitral Contour System implanted in heart failure patients with functional mitral regurgitation (FMR) significantly reduced left ventricular dimensions at one year, and provided clinical improvements through two years, according to the latest data from the TITAN clinical trial, presented by Dr David Reuter in the late breaking clinical trial update session at the Heart Failure 2012 congress.

FMR is a well recognized consequence of the left ventricular remodelling that commonly occurs in heart failure patients. “When hearts dilate, it’s as if the door frame holding the mitral valve leaflets becomes too big with the result that the leaflets don’t close adequately,” explained Dr David Reuter. FMR affects around 90% of patients with heart failure and can increase mortality, with studies suggesting that mild FMR is associated with 10% annual mortality, moderate with 20% and severe with 30 to 40%.

While medical therapies (ACE inhibitors, ARBS, beta blockers and diuretics) offer the standard of care for heart failure patients with FMR, surgical repair in patients undergoing CABG procedures has demonstrated clinical benefits.

The CARILLION® Mitral Contour System, developed by Cardiac Dimensions Inc (Kirkland, Washington), offers a percutaneous approach that can optimise the risk: benefit profile.

The device has been designed to be positioned in the coronary sinus (under fluoroscopic guidance), taking advantage of the heart’s anatomy where the coronary sinus runs parallel to the entire length of the posterior leaflet of the mitral valve. The device, which is made of nitinol, consists of two anchors connected by a shaping ribbon conforming to the natural contours of the coronary sinus. The implant is anchored in two places, resulting in a “reshaping” of the annulus around the mitral valve, with the resultant effect that FMR is reduced. The average time taken for the procedure, which is performed in the catheter lab, is just 38 minutes.

In the Transcatheter Implantation of the CARILLON Mitral Annuloplasty (TITAN) study, 53 patients with FMR and systolic heart failure underwent percutaneous mitral annuloplasty with the CARILLION system. Of these patients, 36 patients had the device left in position and 17 had it recaptured due to reductions in coronary blood flow or insufficient reduction in FMR. 12 and 24 month data for patients fitted with the device was compared to their own baseline data.

The results showed that the 30-day major adverse event (MAE) rate (defined as a composite of death, MI, cardiac perforation, device embolisation and surgery for device failure) was 1.9%.

Mitral regurgitation was reduced from 35 ± 12ml at baseline to 17 ± 12ml through 12 months (P=0.001) for patients fitted with the device. Furthermore, the left ventricular end systolic volume was 152  ± 57ml at baseline versus 121 ± 43ml through 12 months (P=0.015).

The average six minute walk test was 303 ± 74 metres at baseline, 406 ± 180 metres at 12 months, and 450 metres ± 99 metres at 24 months (p=0.005). The NYHA Class improved from 3.1 ± 0.23 at baseline to 2.1 ± 0.64 at 12 months and remained at 2.1 ± 0.74 through 24 months (p<0.001).

In a concluding remark, Dr David Reuter said that, “These data demonstrate the durability of the effect at both 12 and 24 months, and hold out the hope that there may be a subset of patients where, if you intervene at the right time, you could modify the course of the disease.”

 


Source:HEART FAILURE 2012
Compiled and edited by the Editorial team and approved by Expert panel of CardioValens.com

 Other News
First study to evaluate the effectiveness of Functional Electrical Stimulation on exercise capacity, endothelial function and echocardiographic indices of diastolic function in chronic heart failure patients with preserved systolic function
Higher predictive value for malignant ventricular arrhythmias and complex end point for patients with dilated nonischaemic cardiomyopathy and chronic heart failure
Association between hyperglycemia and adverse outcomes observed in AMI patients does not hold true in patients hospitalized with other cardiovascular conditions
Presence of septal asymmetric Hypertrophic cardiomyopathy type is the only independent predictor of increased right atrial volume index
Excellent post-transplant outcomes with mechanical circulatory support as bridge to heart transplantation
Significantly decreased degree of mitral regurgitation or an improved mitral regurgitation, reverse remodeling of left atrium and decrease in left atrium diameters are the benefits with cardiac resynchronization therapy
Myocardial lipid content correlates inversely with left ventricular function in heart failure patients with type 2 diabetes
Periodic use of levosimendan in outpatients with end-stage chronic heart failure is safe and effective in improving quality of life and in reducing re-admissions for worsening heart failure at least in the first eight months of therapy
Highly prevalent severe interatrial mechanical delay in heart failure with preserved ejection fraction is associated with shorter mitral A wave and higher filling pressures
Presence of microalbuminuria is a potential risk marker of events in patients admitted with ACS
Digoxin in high risk Heart Failure patients with reduced ejection fractions
Co-relation between blood pressure/body composition and exercise in hypertensive older overweight individuals
Gender wise analysis of hypertensive patients under a stabilized therapy and without a history of cardiovascular events shows significant differences in the prediction of either stroke or global cardiovascular events or even both
Hygia Project: ingestion of full doses of hypertension medications at bedtime is a proper chronotherapeutic approach and shown to result in improved ambulatory BP control and fewer cardiovascular events
ARB-based aggressive antihypertensive therapy guided by home BP monitoring in patients with diabetes/pre-diabetes is effective in improving cardiovascular target damage
Hypoadiponectinemia and high aldosterone levels in arterial rigidity are responsible for resistance to an antihypertensive therapy
Total cholesterol control can be predicted by only younger age for management of childhood dyslipidemia and hypertension and prevention
Impact of the Combination Antihypertensive Therapy with inclusion of Atorvastatin and Metformin on insulin resistance parameters in patients with the metabolic syndrome and fasting hyperinsulinemia
The combination treatment with Telmisartan, Torasemid and Atorvastatin has positive effects on blood pressure levels and reduces the intensity of heart failure progression in hypertensive's with heart failure class II-III NYHA
Subjects with masked hypertension have an early alteration of diastolic dysfunction
Associations of an increasing plasma insulin levels in patients with metabolic syndrome and post-infarction cardio-sclerosis
Reflected pressure waves in the arm in contrast to central systolic BP do not contribute to the measured arm cuff systolic BP measurements except in Stage 2 hypertension and thereby do not typically influence the diagnosis or staging of systolic hypertension

About Us | Disclaimer |  Privacy Statement | Advertising Info 
info@centrixhealthcare.com © Copyright 2000-2013 Centrix Healthcare Inc. - All Rights Reserved.